5
Electric Hinge with
8 & 4-pin connectors (shown)
or Electric Hinge with 8-pin
connectors only. See note 2
Raceway harness with
8 & 4-pin connectors
Notes:
1. Pigtail assemblies, electric hinge, raceway harness and rail connector terminations and wire colors all match
2. An electric hinge with 8-pin connectors only or 8 & 4-pin connectors is required depending on which Remote Options are required
A. Remote Options requiring an Electric Hinge with 8-pin connectors only :
RM - Remote Monitior
REX - Request to Exit
RP - Remote Power
B. Remote Options requiring an Electric Hinge with 8 & 4-pin connectors :
RR - Remote Reset
DS - Door Status (Tamper) with
or without options listed in A
3. Wire to pigtail harness assemblies per facility requirement
Pigtail harness #1
assembly with
8-pin connector
Pigtail harness #2
assembly with
4-pin connector
1
42
3
AL- 80 Series Rail
with 8 & 4-pin
connectors
(RP, +9) Red, 2
1
75
6
4
3
2
8
(RP, -9) Black, 1
(REX) Orange, 5
(REX) White, 3
(RM - NC) Brown, 8
(RM - C) Blue, 6
(RM - NO) Yellow, 7
I. Wiring to AL- 80 Series Remote Options
(RR) Violet, 1
(DS) Tan, 4
(RR) Grey, 2
(DS) Pink, 3
Hardwire RP (remote power)
& EG (Earth Ground) to
3267 (9vdc) Power Supply
if required. Refer to 3267
instruction A7477
Green (EG), 4
RM - Remote Monitor
REX - Request to Exit
EG - Earth Ground
RP - Remote Power
DS - Door Status (Tamper)
RR - Remote Reset
A7251C
Copyright
©
2004, 2006, 2008, 2009, 2012, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.